久久久久亚洲AV成人无码-国产美女久久精品香蕉69-国产综合久久久久久鬼色-久久这里只有精品18-亚洲女久久久噜噜噜熟女

公司新聞

當前位置:首頁 > 新聞中心 > 公司新聞

如何延長制氮機的使用壽命?

來源:http://m.xingchangweb.com/   日期:2020-09-03   瀏覽量:0
TAG:山東制氮機,山東干燥機,山東螺桿鼓風(fēng)機,山東空壓機,山東自動排水器

  制氮機很多人都有用過,但如何使它的使用壽命延長未必有人了解,以下是一簡單的操作流程。

Many people have used nitrogen machine, but how to prolong its service life may not be understood, the following is a simple operation process.

一、將制氮機、氮氣入口閥以及取樣閥都關(guān)閉,同時也關(guān)閉制氮機的電源開關(guān)。等待系統(tǒng)和管道完全泄壓結(jié)束(系統(tǒng)排出的廢氣為濃縮氧氣,注意消防平安,室內(nèi)空氣流通疏通)。調(diào)節(jié)氧分析儀進行取樣并將減壓閥壓力調(diào)節(jié)到 1.0bar ,調(diào)節(jié)取樣流量計,將氣量調(diào)在 1 左右即可,注意采樣氣量不宜過大 。開始檢測氮氣純度。  二、在壓縮空氣氣源壓力達到 0.7MPa 以上時,打開制氮機總進口的截止閥 ,然后調(diào)節(jié)減壓閥將壓力降低到 0.4-0.5Mpa 左右,同時注意觀察兩個吸附罐的壓力情況以及氣動閥的工作是否能夠正常進行。

1、 Close the nitrogen generator, nitrogen inlet valve and sampling valve, and turn off the power switch of the nitrogen generator. Wait for the complete pressure relief of the system and pipeline (the exhaust gas from the system is concentrated oxygen, pay attention to fire safety, and the indoor air circulation is unblocked). Adjust the oxygen analyzer for sampling, adjust the pressure of the pressure reducing valve to 1.0 bar, adjust the sampling flowmeter to adjust the gas volume to about 1, and pay attention to the fact that the sampling gas volume should not be too large. Start to test the purity of nitrogen. Two, when the compressed air source pressure reaches above 0.7MPa, turn on the total inlet valve of the nitrogen generator, then adjust the pressure reducing valve to reduce the pressure to about 0.4-0.5Mpa. At the same time, observe the pressure of the two adsorption tanks and whether the work of the pneumatic valve can be carried out normally.

三、然后順時針打開 PLC 主站電控柜上的制氮機電源開關(guān)。觀察兩個吸附塔的壓力變化,判斷兩吸附塔是否能夠正常切換。再生塔壓力為零,均勻時兩塔壓力應(yīng)接近原工作塔壓力的一半。


f93cd2ca79cc38245945c4fa68983bc.jpg

3、 Then turn on the power switch of nitrogen generator on the electric control cabinet of PLC master station clockwise. Observe the pressure changes of the two adsorption towers to judge whether the two adsorption towers can switch normally. When the pressure of regeneration tower is zero, the pressure of two towers should be close to half of the original working tower pressure.

四、打開測氧儀的電源開關(guān),并調(diào)節(jié)適量的取樣流量,觀察含氧量。根據(jù)需要的氮氣純度調(diào)節(jié)純度閥的開度,純度合格后自動切換進入氮氣儲罐,儲氮罐儲氮壓力一般為 0.6 0.8MPa 左右。

4、 Turn on the power switch of the oxygen meter, adjust the appropriate amount of sampling flow, and observe the oxygen content. Adjust the opening of the purity valve according to the required nitrogen purity, and automatically switch to the nitrogen storage tank after the purity is qualified. The nitrogen storage pressure of the nitrogen storage tank is generally about 0.60.8mpa.

五、關(guān)閉整個系統(tǒng)和系統(tǒng)各部分,在制氮機吸附罐壓力達到 0.6MPa 左右時,觀察制氮系統(tǒng)是否正常工作。

5、 Close the whole system and all parts of the system, and observe whether the nitrogen generation system works normally when the pressure of adsorption tank of nitrogen generator reaches about 0.6MPa.

六、緩慢打開放空入口截止閥,調(diào)節(jié)流量額定流量的 1/2。調(diào)整氮氣入口閥的開度來調(diào)節(jié)氮氣的純度和流量。

6、 Slowly open the vent inlet stop valve and adjust the flow to 1 / 2 of the rated flow. Adjust the opening of nitrogen inlet valve to adjust the purity and flow of nitrogen.

七、觀察測氧儀指示的氧含量是否符合要求。當?shù)獨饧兌冗_到要求后,再緩慢打開純氣出口截止閥,將流量調(diào)所需的流量,關(guān)閉放空入口截止閥,當設(shè)備正常運轉(zhuǎn)后即可投入使用。

7、 Observe whether the oxygen content indicated by the oxygen meter meets the requirements. When the nitrogen purity meets the requirements, slowly open the pure gas outlet stop valve, adjust the flow to the required flow, close the vent inlet stop valve, and put the equipment into use after normal operation.


上一篇:如何降低螺桿式空壓機的保養(yǎng)成本呢?
下一篇:工業(yè)離心式鼓風(fēng)機選型需要考慮很多方面的因素

久久久久亚洲AV成人无码-国产美女久久精品香蕉69-国产综合久久久久久鬼色-久久这里只有精品18-亚洲女久久久噜噜噜熟女